ZEN Master enables you to configure targets to Pull a channel from a Broadcaster cluster. For resources managed by ZEN Master, the connection configuration is done automatically by ZEN Master. For unmanaged resources you will need to configure the connection manually.

There is an option to create a Dynamic Pull Target. This enables you to connect multiple Receivers (or Zixi-enabled decoders) to the same Target. Each Reciever is monitored separately in ZEN Master and is shown as a Child Target on the Target page. This provides a MeetMe room type of capability for streaming live events to different organizations on an event by event basis.

The following procedure describes how to add a Zixi Pull Target in ZEN Master. In addition, an explanation of each of the configuration parameters is given in the table below.

To add a new Pull Target:

  1. In the main navigation, click Targets.
  2. Click + Add.
    The Create New Target window is displayed.
  3. Click on Zixi.
    The Create New Zixi Target window is displayed.
    Image Removed
    Image Added

  4. In the Info section, in the Name field, enter a logical name for the Pull Target.
  5. In the Access Tags  Tags field, select one or more of the predefined Access Tags from the drop-down list.
    Access Tags are used for access control. By selecting an Access a Tag you are relating this Target target to that Access Tag. Access Tags are associated with certain roles (through the Users & Roles screen), and roles, in turn, are associated with users and user groups. If you would like to create a new Access Tag, see Creating an Access a Tag.
  6. In the Events Configuration Profile field, select from the dropdown list the profile that you would like to apply to this Target. By default, the Default profile is applied.

    Info

    Events Profiles consist of a series of rules that determine precisely how various types of Events are logged and what results they trigger.


  7. The Target's location is used to represent it in the proper position in the Map display (see Maps). By default, the location is determined automatically based on the Target's IP. If you would like to manually set the location of the Target (Optional), use the following procedure:
    1. Click on the Edit icon next to the Location field.
      A search box is shown below the Location field.
    2. Enter identifying info for the location (e.g. street address, zip code, coordinates).
      Search results are displayed below the search box as you type.
    3. Click on the desired location.
      The selected location populates the Location field.
  8. In the Type section, verify that Pull is selected (default).
  9. In the Mode section, select the desired mode. Options are: Single or Dynamic.

    Info

    Dynamic Targets enable you to connect multiple Receivers or other Zixi-enabled devices to the same Target.


  10. Under Channel Type, verify that ZEN Master Channel is selected (default).
  11. In the Channel field, select from the drop-down list the channel that will be sent to the target. (Optional field)

    Info

    The Target will only become functional once a Channel has been assigned to it. However, you can configure the Target settings and then add a Channel to the Target after the initial configuration.


  12. In the Source Preference field, select one of the following options:

    • Any Source – the Target will establish a connection to any available source in the Channel. Upon any disconnects with the current source, the Target will reconnect to another available source in the Channel.
    • Primary Sources Only – the Target will establish and maintain connection to a source designated as Primary in the Channel. Upon loss of connection to that source, the Target will establish a connection to another available Primary source in the Channel.
    • Backup Sources Only – the Target will establish and maintain connection to a source designated as Backup in the Channel. Upon loss of connection to that source, the Target will establish connection to another available Backup source in the Channel.
    • Prefer Primary Sources – if the 
    • Prefer Backup Sources –
    • Specific Source – the Target will only establish a connection to the source specified by the user and will not try to connect to any other source in the Channel.
    In the Device section select the device type of the Pull Target. Options are:
  13. Other – a Zixi-enabled device that is not managed in ZEN Master. You will need to manually configure the connection to the device.
  14. Receiver – a Zixi Receiver that is managed in ZEN Master. ZEN will automatically configure the Receiver to pull the channel.
  15. Broadcaster - a Zixi Broadcaster that is managed in ZEN Master. ZEN will automatically configure the Receiver to pull the channel.

  16. ZEC - a ZEC that is managed in ZEN Master. ZEN ZEN will automatically configure the ZEC to pull the Channel.
    Info

    This selection as well as the following step are relevant only for Single mode. For Dynamic Targets, you will need to connect each Receiver or Zixi-enabled device manually, using the procedure described in Connecting an Unmanaged Pull Target.

    Enter the required information for the selected device type as follows: 
    • For device type Other
      1. In the Receiver Name/ID field, enter the Receiver or Broadcaster name (for a Zixi Receiver/Broadcaster) or Device ID (for other Zixi-enabled device such as IRD or decoder).
      2. To connect the Zixi-enabled device to ZEN Master follow the procedure described in Connecting an Unmanaged Pull Target.
    • For device type Receiver
    • In the Receiver field, select from the drop-down list a Receiver that is managed by ZEN Master.
    • In the Receiver Output field, select one or more of the Receiver's outputs. (Optional field)

      Info

      If you would like to remove the selected Broadcaster Output, click on the 'X' in the Receiver Output textbox.

      In the Input NICs field, if you would like to specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected.

      Info

      Multiple NICs are only supported in Active/Active Failover mode.

      For device type Broadcaster
    • In the Broadcaster field, select from the drop-down list a Broadcaster that is managed by ZEN Master.
    • In the Broadcaster Output field, select one or more of the Broadcaster– when this setting is selected, if there is a primary source and a backup source with the same status, ZEN Master will prefer the primary source. However, for example, if the backup source has an OK status and the primary source has a Frozen Video detected error, the backup source will be selected.  
    • Prefer Backup Sources – when this setting is selected, if there is a primary source and a backup source with the same status, ZEN Master will prefer the backup source. However, for example, if the primary source has an OK status and the backup source has a Frozen Video detected error, the backup source will be selected. 
    • Specific Source – select one of the specific sources listed. The Target will only establish a connection to the selected source and will not try to connect to any other source in the Channel.

      Info

      If it is not possible to select "Prefer Primary Sources" or "Prefer Backup Sources". This means you cannot have a Target failover from a Primary to a Backup source in the Channel unless "Any Source" is selected.


  17. In the Device section select the device type of the Pull Target. Options are:
    • Other – a Zixi-enabled device that is not managed in ZEN Master. You will need to manually configure the connection to the device.
    • Receiver – a Zixi Receiver that is managed in ZEN Master. ZEN will automatically configure the Receiver to pull the channel.
    • Broadcaster - a Zixi Broadcaster that is managed in ZEN Master. ZEN will automatically configure the Receiver to pull the channel.

    • ZEC - a ZEC that is managed in ZEN Master. ZEN ZEN will automatically configure the ZEC to pull the Channel.


      Info

      This selection as well as the following step are relevant only for Single mode. For Dynamic Targets, you will need to connect each Receiver or Zixi-enabled device manually, using the procedure described in Connecting an Unmanaged Pull Target.


  18. Enter the required information for the selected device type as follows: 
    • For device type Other
      1. In the Receiver Name/ID field, enter the Receiver or Broadcaster name (for a Zixi Receiver/Broadcaster) or Device ID (for other Zixi-enabled device such as IRD or decoder).
      2. To connect the Zixi-enabled device to ZEN Master follow the procedure described in Connecting an Unmanaged Pull Target.
    • For device type Receiver
      1. In the Receiver field, select from the drop-down list a Receiver that is managed by ZEN Master.
      2. In the Receiver Output field, select one or more of the Receiver's outputs. (Optional field)

        Info

        If you would like to remove the selected Broadcaster Output, click on the click on the 'X' in the Broadcaster Receiver Output textbox.


      3. In the Input NICs field, if you would like to specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected.

        Info

        Multiple NICs are only supported in Active/Active Failover mode.


    • For device type ZEC  Broadcaster
      1. In the ZEC Broadcaster field, select from the drop-down list a ZEC Broadcaster that is managed by ZEN Master.
      2. In the ZEC Broadcaster Output field, select one or more of the ZECBroadcaster's outputs. (Optional field)

        Info

        If you would like to remove the selected ZEC Broadcaster Output, click on click on the 'X' in the ZEC Broadcaster Output textbox.


      3. In the Input NICs field, if you would like to specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected.

        Info

        Multiple NICs are only supported in Active/Active Failover mode.


    • For device type ZEC 
      1. In the
    Password
      1. ZEC field,
    enter a password for accessing the Channel OR click Random to generate a random password. (Optional field)
  19. In the Latency field, enter the latency in milliseconds OR leave empty to use remote configuration (default).
  20. In the Encryption section
      1. select from the drop-down list a ZEC that is managed by ZEN Master.
      2. In the ZEC Output field, select one or more of the ZEC's outputs. (Optional field)

        Info

        If you would like to remove the selected ZEC Output, click on the ‘X’ in the ZEC Output textbox.


      3. In the Input NICs field, if you would like to

    encrypt the stream, select one of the encryption methods. Options are: Disabled (default), AES 128, AES 192 or AES 256.
  21. If Encryption was selected, in the Encryption Key field, enter an encryption key that will be used to encrypt the connection OR click Random to generate a random encryption key.
  22. Select Prefer Private Broadcaster IP if you would like ZEN to configure connections to to use private broadcaster IPs when available. The default behavior when this is not selected is to prefer use of public IPs.

  23. In the Failover Mode section, select the desired mode, options are:
  24. Alternative Hosts – the receiver pulls a single Source at a time and reconnects when an error occurs. (Default)
  25. Active/Active - the receiver pulls both Sources together. On v12.2+ Receivers this creates a hitless failover stream. On earlier Receivers it creates two inputs for a single output.

    Info

    Active/Active mode is only available for outputs that are configured as Hitless Failover.

  26. In the Initial State section, select the Disabled checkbox if you would like to disable this Target upon initial configuration.
  27. Select the Muted checkbox if you would like to disable error/recovery notifications for this Target upon initial configuration.

    Info

    You can Enable/Unmute the Target at any time.

  28. If you would like to configure Advanced settings, click on Advanced.
    The Advanced settings are shown.
    Image Removed
  29. In the Failover Latency [ms] field, enter the desired latency. Default: 5000
  30. If you would like to use the Target name as the Stream ID, select the Use Name as Stream ID checkbox.

    Info

    The default behavior is that ZEN Master automatically generates the Stream ID. In general, leaving the default behavior is recommended.

  31. If you would like to track usage for this Target, enter your Billing Code details, see Billing Codes. (Supported for Broadcasters v14.8+)
  32. Click Save.

Zixi Pull Target Configuration Parameters Table

Parameter

Description

Info

Name

Specify a name for the Zixi Pull Target in ZEN Master.

Access Tags

Select one or more of the predefined Access Tags from the drop-down list.

Access Tags are used for access control. By selecting an Access Tag, you are relating this Target to that Access Tag. Access Tags are associated with certain roles (through the Users & Roles screen), and roles, in turn, are associated with users and user groups. If you would like to create a new Access Tag, see Creating an Access Tag.

Events Configuration Profile

Select from the dropdown list the profile that you would like to apply to this Target. By default, the Default profile is applied.

Note: Events Profiles consist of a series of rules that determine precisely how various types of Events are logged and what results they trigger.

Location (Optional)The Target's location is used to represent it in the proper position in the Map display (see Maps). By default, the location is determined automatically based on the Target's IP. Enter identifying info for the location (e.g. street address, zip code, coordinates) and select the desired location from the suggestions that are shown.

Configuration

Type

Verify that Pull is selected (default).

Mode

In the Mode section, select the desired mode. Options are:

  • Single - connect a single Receiver or Zixi-enabled device to this Target.
  • Dynamic - connect multiple Receiver's and/or Zixi-enabled devices to this Target.

Channel Type

Verify that ZEN Master Channel is selected (default).

Channel

(Optional)

Select from the drop-down list the Channel that will be sent to the Target.

Note: The Target will only become functional once a Channel has been assigned to it. However, you can configure the Target settings and then add a Channel to the target after the initial configuration.

Source Preference

Select from the drop-down list one of the following:

  • Any Source – the Target will establish a connection to any available source in the Channel. Upon any disconnects with the current source, the Target will reconnect to another available source in the Channel.
  • Primary Sources Only – the Target will establish and maintain connection to a source designated as Primary in the Channel. Upon loss of connection to that source, the Target will establish a connection to another available Primary source in the Channel.
  • Backup Sources Only – the Target will establish and maintain connection to a source designated as Backup in the Channel. Upon loss of connection to that source, the Target will establish connection to another available Backup source in the Channel.
  • Prefer Primary Sources –
  • Prefer Backup Sources –
  • Specific Source – the Target will only establish a connection to the source specified by the user
        1. specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected

          Info

          Multiple NICs are only supported in Active/Active Failover mode.


    1. In the Password field, enter a password for accessing the Channel OR click Random to generate a random password. (Optional field)
    2. In the Latency field, enter the latency in milliseconds OR leave empty to use remote configuration (default).
    3. If you would like to apply a PID Mapping profile to this Target, then in the PID Mapping Profile field, select the desired profile from the dropdown list. For more information, see PID Mapping Profiles.
    4. In the Encryption section, if you would like to encrypt the stream, select one of the encryption methods. Options are: Disabled (default), AES 128, AES 192 or AES 256.
    5. If Encryption was selected, in the Encryption Key field, enter an encryption key that will be used to encrypt the connection OR click Random to generate a random encryption key.
    6. Select Prefer Private Broadcaster IP if you would like ZEN to configure connections to to use private broadcaster IPs when available. The default behavior when this is not selected is to prefer use of public IPs.

    7. In the Failover Mode section, select the desired mode, options are:
      • Alternative Hosts – the receiver pulls a single Source at a time and reconnects when an error occurs. (Default)
      • Stream Switch - the receiver pulls both Sources together. On v12.2+ Receivers this creates a hitless failover stream. On earlier Receivers it creates two inputs for a single output.

        Info

        Active/Active mode is only available for outputs that are configured as Hitless Failover.


    8. In the Initial State section, select the Disabled checkbox if you would like to disable this Target upon initial configuration.
    9. Select the Muted checkbox if you would like to disable error/recovery notifications for this Target upon initial configuration.

      Info

      You can Enable/Unmute the Target at any time.


    10. If you would like to configure Advanced settings, click on Advanced.
      The Advanced settings are shown.
      Image Added
    11. In the Failover Latency [ms] field, enter the desired latency. Default: 5000
    12. If you would like to use the Target name as the Stream ID, select the Use Name as Stream ID checkbox.

      Info

      The default behavior is that ZEN Master automatically generates the Stream ID. In general, leaving the default behavior is recommended.


    13. If you would like to track usage for this Target, enter your Billing Code details, see Billing Codes. (Supported for Broadcasters v14.8+)
    14. Click Save.


    Zixi Pull Target Configuration Parameters Table

    Parameter

    Description

    Info

    Name

    Specify a name for the Zixi Pull Target in ZEN Master.

    Tags

    Select one or more of the predefined Tags from the drop-down list.

    Tags are used for access control. By selecting a Tag, you are relating this Target to that Tag. Tags are associated with certain roles (through the Users & Roles screen), and roles, in turn, are associated with users and user groups. If you would like to create a new Tag, see Creating a Tag.

    Events Configuration Profile

    Select from the dropdown list the profile that you would like to apply to this Target. By default, the Default profile is applied.

    Note: Events Profiles consist of a series of rules that determine precisely how various types of Events are logged and what results they trigger.

    Location (Optional)The Target's location is used to represent it in the proper position in the Map display (see Maps). By default, the location is determined automatically based on the Target's IP. Enter identifying info for the location (e.g. street address, zip code, coordinates) and select the desired location from the suggestions that are shown.

    Configuration

    Type

    Verify that Pull is selected (default).

    Mode

    In the Mode section, select the desired mode. Options are:

    • Single - connect a single Receiver or Zixi-enabled device to this Target.
    • Dynamic - connect multiple Receiver's and/or Zixi-enabled devices to this Target.

    Channel Type

    Verify that ZEN Master Channel is selected (default).

    Channel

    (Optional)

    Select from the drop-down list the Channel that will be sent to the Target.

    Note: The Target will only become functional once a Channel has been assigned to it. However, you can configure the Target settings and then add a Channel to the target after the initial configuration.

    Source Preference

    Select from the drop-down list one of the following:

    • Any Source – the Target will establish a connection to any available source in the Channel. Upon any disconnects with the current source, the Target will reconnect to another available source in the Channel.
    • Primary Sources Only – the Target will establish and maintain connection to a source designated as Primary in the Channel. Upon loss of connection to that source, the Target will establish a connection to another available Primary source in the Channel.
    • Backup Sources Only – the Target will establish and maintain connection to a source designated as Backup in the Channel. Upon loss of connection to that source, the Target will establish connection to another available Backup source in the Channel.
    • Prefer Primary Sources – when this setting is selected, if there is a primary source and a backup source with the same status, ZEN Master will prefer the primary source. However, for example, if the backup source has an OK status and the primary source has a Frozen Video detected error, the backup source will be selected.
    • Prefer Backup Sources – when this setting is selected, if there is a primary source and a backup source with the same status, ZEN Master will prefer the backup source. However, for example, if the primary source has an OK status and the backup source has a Frozen Video detected error, the backup source will be selected. 
    • Specific Source – select one of the specific sources listed. The Target will only establish a connection to the selected source and will not try to connect to any other source in the Channel.

    Device (for Single mode)

    Select the device type of the Pull Target. Options are:

    • Other – a Zixi-enabled device that is not managed in ZEN Master. You will need to manually configure the connection to the device. 
    • Receiver – a Zixi Receiver that is managed in ZEN Master. ZEN will automatically configure the Receiver to pull the Channel.
    • Broadcaster - a Zixi Broadcaster that is managed in ZEN Master. ZEN will automatically configure the Receiver to pull the Channel.
    • ZEC – a ZEC that is managed in ZEN Master. ZEN will automatically configure the ZEC to pull the Channel.

    For Other Device Type

    Receiver Name/ID

    Enter the Receiver or Broadcaster name (for a Zixi Receiver/Broadcaster) or Device ID (for other Zixi-enabled device such as IRD or decoder).

    Note: To connect the Zixi-enabled device to ZEN Master follow the procedure described in Connecting an Unmanaged Pull Target.

    For Receiver Device Type

    Receiver

    Select from the drop-down list a Receiver that is managed by ZEN Master.

    Receiver Output

    (Optional)

    Select one or more of the Receiver's outputs.

    Note: If you would like to remove the selected Receiver Output, click on the ‘X’ in the Receiver Output textbox.

    Input NICs

    If you would like to specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected.

    Note: Multiple NICs are only supported in Active/Active Failover mode.

    For Broadcaster Device Type

    Broadcaster

    Select from the drop-down list a Broadcaster that is managed by ZEN Master.

    Broadcaster Output

    (Optional)

    Select one or more of the Broadcaster's outputs.

    Note: If you would like to remove the selected Broadcaster Output, click on the ‘X’ in the Broadcaster Output textbox.

    Input NICs

    If you would like to specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected.

    Note: Multiple NICs are only supported in Active/Active Failover mode.

    For ZEC Device Type

    ZEC

    Select from the drop-down list a ZEC that is managed by ZEN Master.

    ZEC Output (Optional)

    Select one or more of the ZEC's outputs.

    Note: If you would like to remove the selected ZEC Output, click on the ‘X’ in the ZEC Output textbox.

    Input NICs

    If you would like to specify which NICs are used, then select the IPs of one or more NICs from the drop-down list. By default, Any is selected.

    Note: Multiple NICs are only supported in Active/Active Failover mode.

    For All Device Types

    Password

    (Optional)

    Enter a password for accessing the Channel OR click Random to generate a random password.

    Latency [ms]

    Enter the latency in milliseconds OR leave empty to use remote configuration (default)remote configuration (default).

    PID Mapping Profile (optional)If you would like to apply a PID Mapping profile to this Target, then select the desired profile from the dropdown list.
    To create a new PID Mapping Profile, see Adding PID Mapping Profiles.

    Encryption

    If you would like to encrypt the stream, select one of the encryption methods. Options are: Disabled (default), AES 128, AES 192 or AES 256.

    Encryption Key

    (for Encryption enabled)

    Enter an encryption key that will be used to encrypt the connection OR click Random to generate a random encryption key.

    Prefer Private Broadcaster IP

    Select this checkbox if you would like ZEN to configure connections to use private broadcaster IPs when available. The default behavior when this is not selected is to prefer use of public IPs.

    Failover Mode

    Select the desired mode, options are:

    • Alternative Hosts – the receiver pulls a single Source at a time and reconnects when an error occurs. (Default)
    • Active/Active Stream Switch - the receiver pulls both Sources together. On v12.2+ Receivers this creates a hitless failover stream. On earlier Receivers it creates two inputs for a single output.

    Note: Active/Active mode is only available for outputs that are configured as Hitless Failover.

    Initial State
    DisabledSelect this checkbox if you would like to disable this Target upon initial configuration.
    MutedSelect this checkbox if you would like to disable error/recovery notifications for this Target upon initial configuration.

    Advanced

    Failover Latency [ms]

    Specify the desired latency. Default: 5000 ms.

    Use Name as Stream ID

    If you would like to use the Target name as the Stream ID, select this checkbox.

    Note: The default behavior is that ZEN Master automatically generates the Stream ID. In general, leaving the default behavior is recommended.

    Billing CodesCodeIf you would like to track usage for this Target, enter your Billing Code details, see Billing Codes. (Supported for Broadcasters v14.8+)
    Billing PasswordEnter the password that corresponds to this billing code.
    External IDThe ID that is used when integrating ZEN Master with an external ESNI/ESAM server. For more detail, contact your Zixi representative.