The Details section shows the following information:
Parameter
Description
Name
The name of the PID Mapping profile.
Access Tags
The Access Tag/s that is associated with this profile.
Default Action
The default action that is applied to PIDs that are not included in a specific rule.
Pass – passes the PIDs through unchanged, with the existing PID numbers.
Set Null – sets the PID value as null. This is useful for maintaining the integrity of CBR streams.
Remove – removes the PIDs from the stream.
Type
The method used for specifying which PIDs the rules apply to. Options are:
PID - the number of the incoming PID
Category – the general category of the PID (e.g. audio, video, SCTE-35 etc.). If the stream has multiple PIDs of the specified category, then the rule is applied to the first PID and all others are treated with the default process.
Type – the specific type codec (e.g. MPEG1 Video, AVCH/.264, HEVC etc.)