The NSI is pulled into Zixi Broadcaster using the auto-discovery mechanism described in the NDI Stream Discovery section.
To Add an NDI Input Stream:
In the Zixi Broadcaster Navigation menu, click the Inputs tab.
In the Menu bar, click New Input. The Add a new input stream window is displayed.
Select NDI for the input stream.
Select the maximum concurrent connections to this stream from the Max. Outputs drop-down list. Default: Unlimited.
Select the Show in Matrix check box to display this stream in the Matrix (see ). Default: Selected.
Specify the Stream Parameters (see Input Stream Parameter table).
If you want to Enable time shift, select this checkbox (see Input Stream Parameter table). The stream will be recorded and broadcasted after the specified delay. The time shift feature is typically used to broadcast a live event across time zones (due to the time differences between locations).
If you want to Transmit as multicast, select this checkbox (see Input Stream Parameter table).
If you want to configure the Recording Parameters, specify them in the respective fields (see Input Stream Parameter table).
If you want to Enable encryption, select this checkbox (see Input Stream Parameters Table). For more information, see Encrypting an Input Stream in Zixi Broadcaster.
Click OK. The “Input added” message appears on the top of the screen. The NDI Stream is added to the Zixi Broadcaster and now appears in the list of streams available in Zixi Broadcaster Inputs screen.