Adding CDI Targets
- alon.men@zixi.com
- Alon Men
- Eli Pielet (Writec) (Unlicensed)
CDI targets are supported only on Flows that have an EFA VPC interface with a CDI or JPEG XS Source. You can configure an AWS MediaConnect "Flow" that has already been set up in your MediaConnect account to be used in the CDI Target in ZEN Master.
In order to use this feature, you must first link ZEN Master to an AWS account, see Linking an AWS Account
The following procedure describes how to add an CDI Target in ZEN Master. In addition, an explanation of each of the configuration parameters is given in the table below.
To add a new CDI Target:
- In the main navigation, click Targets.
- Click + Add.
The Create New Target window is displayed. - Click on CDI.
The Create New CDI Target window is displayed. - In the Info section, in the Name field, enter a logical name for the CDI Target.
- In the Tags field, select one or more of the predefined Tags from the drop-down list.
Tags are used for access control. By selecting a Tag you are relating this target to that Tag. Tags are associated with certain roles (through the Users & Roles screen), and roles, in turn, are associated with users and user groups. If you would like to create a new Tag, see Creating a Tag. In the Events Configuration Profile field, select from the dropdown list the profile that you would like to apply to this Target. By default, the Default profile is applied.
Events Profiles consist of a series of rules that determine precisely how various types of Events are logged and what results they trigger.
- Under the Configuration section, in the AWS MediaConnect Flow field, select from the drop-down list a MediaConnect Flow that have an EFA VPC interface with a CDI or JPEG XS Source.
- In the IP and Port fields, specify the connection details to the CDI target.
- In the Initial State section, select the Disabled checkbox if you would like to disable this Channel upon initial configuration.
Select the Muted checkbox if you would like to disable error/recovery notifications for this Channel upon initial configuration.
You can Enable/Unmute the Channel at any time.
- Click Save.
CDI Target Configuration Parameters Table
Parameter | Description |
Info | |
---|---|
Name | Specify a name for the CDI Target in ZEN Master. |
Tags | Select one or more of the predefined Tags from the drop-down list. Tags are used for access control. By selecting a Tag, you are relating this Target to that Tag. Tags are associated with certain roles (through the Users & Roles screen), and roles, in turn, are associated with users and user groups. If you would like to create a new Tag, see Creating a Tag. |
Events Configuration Profile | Select from the dropdown list the profile that you would like to apply to this Target. By default, the Default profile is applied. Note: Events Profiles consist of a series of rules that determine precisely how various types of Events are logged and what results they trigger. |
Location (Optional) | The Target's location is used to represent it in the proper position in the Map display (see Maps). By default, the location is determined automatically based on the Target's IP. Enter identifying info for the location (e.g. street address, zip code, coordinates) and select the desired location from the suggestions that are shown. |
Configuration | |
MediaConnect Flow | Select from the drop-down list a MediaConnect Flow that have an EFA VPC interface with a CDI or JPEG XS Source. |
IP | Enter the IP address of the Target |
Port | Enter the port that will be used to connect to the Target. |
Initial State | |
Disabled | Select this checkbox if you would like to disable this Target upon initial configuration. |
Muted | Select this checkbox if you would like to disable error/recovery notifications for this Target upon initial configuration. |