Multiple source nodes can be configured to PUSH to a single Zixi target Input. Contention for the input is decided on a first-come first-served basis. If the primary source connection is lost, the target Input will automatically accept a new stream (coming from the secondary source). As a result, this topology provides source-side redundancy with automated fail-over to a second identical stream.
Source Configuration
The following procedure describes how to configure two Zixi Feeder to push a single stream to a target hosts in a warm redundancy configuration. The procedure does cover instructions on how to configure the Input into the Zixi Feeder.
To configure the primary source node (e.g. Zixi Feeder):
On the Outputs page of Zixi Feeder, click the New Output button, located in the upper- right end corner of the screen.
In the Name field, type a new name for the output.
In the Type field select Push to Broadcaster.
Under Input, in the Input Name field select the relevant name of the input stream .
Under Properties, in the Stream ID field enter a stream ID (alphanumeric). The same Stream ID will be also configured in the target node.
Set the desired Max Latency in milliseconds
In the Host field, enter the host name or IP of the target.
Click OK to create the primary output.
To configure the secondary source node (e.g. Zixi Feeder):
On the Outputs page of Zixi Feeder, click the New Output button, located in the upper- right end corner of the screen.
In the Name field, type a new name for the output.
In the Type field select Push to Broadcaster.
Under Input, in the Input Name field select the relevant name of the input stream .
Under Properties, in the Stream ID field enter the same stream ID as the one used in the primary source.
Set the desired Max Latency in milliseconds
In the Host field, enter the host name or IP of the target (the same as the one configured in the primary source).
Click OK to create the secondary output.
Target Configuration
The following procedures describe how to configure the target Zixi Broadcaster in a warm redundancy configuration. The target is configured with a single input. If this input is unavailable the secondary input will be received. The input must use the same Stream ID that was used to configure the primary and secondary Source Zixi Feeders.
To configure the target node (e.g. Zixi Broadcaster):
Click the Inputs tab at the top of the Zixi Broadcaster administrative screen
Click New Input on the upper right hand side of the screen.
Select the Push option.
Create an input, while ensuring the “Stream ID” matches that of the primary and secondary sources output.
Configure additional parameters as required.
Click OK.
Cost Considerations
This topology duplicates the source side Zixi node software and hardware components. It does not require doubling the up-link bandwidth, as the backup connection stream is only active in the event that the primary stream fails.
Latency Considerations
Primary Connection loss =
Retry cycle =
Connection to secondary =
Total recovery Time =