Redundant streams can be delivered over multiple Network Interface Cards (NICs) in either a PUSH or PULL configuration.
Source Configuration
To configure the primary source node (e.g. Zixi Receiver):
- On the Inputs page of the primary Zixi Receiver, click on the upper- right end corner of the screen.
- In the Output Name field, type a new name for the output.
- In the Input Stream field, select the relevant input stream.
- Select the Push option.
- In the Output Parameters section, under Links, enter the details of the target, including:
The target Host - Specify the destination Broadcaster name or IP address to which you are pushing the stream.
The Port number - Specify the ports to listen on for Push streams. Default - 2088
Target IP - - Set the desired Max Latency in milliseconds.
- Click OK to create the primary output,