- Make sure at least one of the existing inputs has the Enable time shift setting selected.
- In the ZEC Navigation menu, click the Inputs
- In the Menu bar, click New Input. The Add a new input stream window is displayed.
Enter the unique Stream ID.
- Select the maximum concurrent connections to this stream from the Outputs drop-down list. Default: Unlimited.
- Select the Show in Matrix check box to display this stream in the Matrix (see Using the Matrix). Default: Selected.
- Select Delayed for the input stream.
- Specify the Stream Parameters (see Input Stream Parameters Table).
- If you want to Transmit as multicast, select this checkbox (see Input Stream Parameters Table).
- Click OK. The “Input added” message appears on the top of the screen. The Delayed Stream is added to ZEC and now appears in the list of streams available in the ZEC inputs UI.
Input Stream Parameters Table
ParameterDescriptionStream Parameters
The general stream settings.
Source
Select one of the input streams that were configured to enable "time shift".
Delay
Specify the delay period relative to the original stream in the following format: hh:mm:ss.
Transmit as multicast
Select this checkbox to enable the transmission of this stream’s outputs as multicast. A Zixi receiver ZEC that will pull the stream will receive it in multicast. By default ZEC is configured to allow transparent fallback to unicast if it is out of the LAN. Requires enabling Multicast Pull in the Settings.
Multicast-Only (for Multicast enabled)
If desired, specify multicast only outputs.
...